Beltstation will not power up
Confirm that battery(ies) is (are) installed correctly.
When using a Lithium-Polymer rechargeable battery, ensure that the battery is fully charged.
When using alkaline AA batteries ensure that batteries are fresh and are all facing the same way. Note
the illustration in the battery compartment.
Press and hold the Power button on the back of the beltstation for 2 seconds to power on.
Beltstation will not Pair with Base Station
Confirm that the base station you are Pairing with is powered on and in Operational Mode and the
beltstation is powered off. Connect the Pairing cable from the base station to the beltstation. Turn the
beltstation power on. The Pairing process takes approximately four seconds.
If Pairing is successful the message “Pairing Complete” will appear on the beltstation LCD for
approximately five seconds and the beltstation name will appear in the first available slot on the base
station LCD. The base station name will appear on the beltstation LCD.
If Pairing is not successful no message will appear.
If Pairing is not successful try to Pair a different beltstation with the base station. If neither of the
beltstations will Pair, substitute a new Pairing cable.
If successful Pairing any beltstation with the base station, try the following procedure on the beltstation
that will not Pair:
Restore memory settings to Factory Defaults by pressing MENU, select “Belt Settings;” select “Tech
Menu;” press ENTER to proceed; select “Set Defaults;” select “Restore Factory Defaults;” press ENTER
to confirm; press MENU repeatedly to exit. If still not successful, repeat the above procedure but select
“Clear Memory” to delete all memory settings, Pairings, and user settings.
If no beltstation will Pair with the base station, reset the base station memory to “Factory Defaults”.
The final option is to select “Clear Memory” to fully reset the base station. All beltstation Pairings will be
lost with the “Clear Memory” option.
Beltstation will not log into Base Station
Confirm that the beltstation is powered on and has a battery with ample charge.
Confirm that the proper base station is selected on the beltstation’s Select Base menu.
Confirm that there is an available slot on the base station.
Check Static / Dynamic display settings on the base station. If Static is selected check the beltstation slot
assignment.
Determine if any beltstation is logged on to the base station.
Re-Pair the beltstation to the base station.
Attempt to log into another base station, if available.
Follow the memory reset procedure.
Buttons on the Beltstation do not function
A number of buttons on the beltstation can have alternate functions that the user can select.
If a button on the beltstation is not working as expected, re-confirm all settings and any alternate function
assignment in the menu. The button may have been reassigned wirelessly from the base station or by T-
Desk. Confirm that the function is available for use. If the reassignment involves any GPO, confirm that
menu selection, the connections, and the equipment functionality.