Clear-Com TEMPEST 2400 Especificaciones Pagina 49

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 100
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 48
Clear-Com Communication Systems Page 49 of 100
Tempest 2400 Wireless Intercom System
Accu-Sync
Three Base Stations Accu-Synced
Accu-Sync provides a common timing signal between connected base stations. This signal ensures that
transmission cycles for all Accu-Synced base stations occur simultaneously. This synchronized
transmission eliminates the negative RF effect called desensing. See the following section, “Special RF
Considerations for Multiple base stations”, for more information on connecting multiple base stations.
When two or more Tempest base stations are to be operated in the same location, connecting the base
stations via the BaseSync connector on the back of the base station minimizes potential RF interference
between base stations. The more base stations there are in close proximity to each other the more
important it is to use Accu-Sync.
One base station must always act as the sync source when using Accu-Sync. The sync source is any
base station that does not have a BaseSync cable plugged into the BaseSync IN connector. Always
ensure that one, and only one base station has an open (no connection) BaseSync IN connector.
When a base station does not have a BaseSync cable plugged into the BaseSync IN connector, that base
station uses an internally generated timing pulse to control its own transmission cycle.
When a base station has a BaseSync cable plugged into the BaseSync IN connector, that base station
uses the external sync signal (timing pulse) to control its transmission cycle.
The BaseSync signal is enabled by default but can be disabled in the Tech Menu under Radio
Configuration. Unless directed by Tech Support personnel, BaseSync should remain enabled.
The BaseSync cable is a DB-9F To DB-9M wired straight through on pins 1-5.
BASESYNC IN
Accu-Sync - DB-9 Connector
Never connect Accu-Sync cables between 2.4GHZ and 900MHz Tempest models.
Vista de pagina 48