Clear-Com WBS-670 Instrucciones de operaciones Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 62
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
Scan
Scan performs a frequency scan of the factory-defined and
any set-up user-programmable groups in order to find the
clearest group. After about 30 seconds, the clearest group is
displayed. A group is defined by the receive frequency. The
next best group and so forth may be accessed with the
[DOWN] and [UP] arrow buttons.
Press and hold [MENU] + [SET] for three seconds to en
-
ter Scan. The beltpack will now start searching for the
clearest groups. The group symbol will flash indicating
the beltpack is scanning for clear groups.
Scan will scan all groups. It will then display the 1
st
group it came to that had the clearest receive channel. The
[UP] / [DOWN] buttons may be used to select the next
best group and so forth. Hit [SET] to place the beltpack
on this group and return to the group/channel screen.
6-17